AC Input | Input Voltage Range | 260 ~ 550 Vac |
Input Current | <60 A (max) | |
Frequency Range | 45 ~ 65 Hz | |
Power Factor | ≥0.98 | |
Efficency | >97% (Full Load) | |
ITHD | <5% | |
DC Output | Output Power | 30kW |
Output Voltage Range | 50 ~ 1000 Vdc | |
Output Current | 0 ~ 100 A | |
Current Sharing | ±1% | |
Voltage Balancing | ±0.5% | |
Current Balancing | ±1% | |
Ripple Peak to Peak | ±1% | |
Environment | Storage Temperature | -40 ~ +75 °C |
Cooling Mode | Fan Cooling | |
Control | Communication | CAN BUS |
Indication Light | Green: Normal Operation Yellow: Alarm Red: Fault |
|
Parallel Module Quantity | ≤50 Piecies | |
Protection Function | Input Over/Under Voltage Protection | Auto Shutdown, Automatic Restart (When voltage returns to normal range) |
Output Over Voltage Protection | Automatic Shutdown and Lock (Need the input restart to unlock) | |
Output Current | Automatic Shutdown and Lock (Need the input restart to unlock) | |
Short Circuit Protection | Automatic Shutdown and Lock (Need the input restart to unlock) | |
Over Temperature Protection | Auto Shutdown, Automatic Restart (When temperature returns to normal range) | |
Reliablity and Safety | MTBF | >500,000 Hours |
Safety | Compliant with CE, EMC Standard | |
Mechanical | Dimensions | 120mm (H) × 360mm (W) × 390mm (D) |
Weight | ≤23 Kgs | |
Others | Standby Power Consumption | 15W ±1.0W |
• Extensive Output Voltage Range: Operates from 100 to 1000 VDC, adaptable for a wide range of electric vehicle models.
• High Output Power: Capable of constant power output across a range of 300 to 1000 VDC, providing up to 30 kW of continuous power.
• Temperature Resilience: Wide operating temperature range from -40°C to +75°C, suitable for various environments.
• High Efficiency: Achieves full load efficiency greater than 97%, optimizing energy use and reducing operational costs.
• Low Standby Power Consumption: Consumes less than 15 W in standby mode, enhancing energy savings when not in active use.
• Reduced Noise: Designed to minimize noise, improving the overall user charging experience.
• Enhanced Low-Voltage Charging: Maintains high current in low-voltage areas, ensuring faster charging speeds.
• Intelligent Discharge and Protection: Features a built-in residual pressure relief loop for automatic discharge of residual power, simplifying system designs and enhancing reliability.
• Active Power Factor Correction (PFC): Uses three-phase four wire active PFC technology to reduce harmonic interference in the grid, ensuring stable and efficient power delivery.
• Advanced DSP Control: Dual DSP design for comprehensive digital control, reducing component count for enhanced reliability.
• Wide Input Voltage Range: Accepts input from 260 to 530 VAC, allowing operation even in challenging grid conditions.
• Plug & Play Interface: Simplified installation and integration with a user-friendly, plug-and-play interface.
• CAN Interface: Includes a CAN communication interface for easy integration into advanced systems.
© 2025 AneVa Instruments Private Limited. All Right Reserved